Maintenance Tips to Avoid Headaches and Product Losses

 

Exhaust Fan Belts:

  • Re-adjust belt tension after 8 – 10 hours of operation.
  • Check for proper belt tension by pushing on belt between blade pulley and motor pulley with index finger. Belt should move about ½ inch with 5 pounds of pressure. Keep replacement belts on hand.
  • Check belts at beginning of cooling season and several times throughout year.
  • Look for polished sides and cracked, dry, and/or brittle material.
  • Replace belt if any signs of deterioration or if in use for several seasons.
  • Clean fan blades and louvers as needed.
  • Remove foreign material from inside fan housing.

Versa-Vent:

  • See installation manual for adjustment of drive motor limits
  • Rack and pinions may be adjusted by loosening nuts on vent shoe where rack attaches to vent door
  • Shift rack shoe left or right to improve alignment
  • Check the alignment with the vent door open
  • Clean the entire vent including the cover with soap and water
  • Remove accumulated debris in the lower track of vent door

Carolina Cooler™:

  • If float valve is unable to shut off, cut off water supply, disassemble and rinse float valve, reassemble and install
  • If after above (if float valve still will not shut off), order a rebuild kit or new valve
  • Rinse out reservoir and fill with clean water at the beginning of the season
  • Do not leave in ground tanks empty
  • Clean the filter as well and several times throughout the year
  • Check the filter if flow seems restricted
  • Check the header for clogs
  • Rinse out the header at the beginning of the season – remove the plug opposite
  • the pump and then run the pump to flush out foreign material
  • Add chlorine bleach or any good algaecide to the reservoir on a regular basis to keep pads clean
  • Maintain a pH between 5.5 and 8.5 in the reservoir
  • Allow pads to dry completely each night by keeping the thermostat set above the overnight low temperature
  • Use the gate valve to adjust the water flow so that the water sprays 12” into the air at the far end of the header from the pump

PDF

 

More Articles Like This

How to Prepare Your Greenhouse for a Hurricane

Our Engineer compiled the following list of suggestions assuming the worst-case scenario of extremely high winds from Hurricanes.

Gas Heater Service Checklist for Fall

Be Sure To Do The Following Preventive Maintenance Before Starting Your Heaters Each Fall.

How to Get the Best Performance from Your Greenhouse

Seasonal maintenance is the key to maximizing the performance of your greenhouse. The following is an abbreviated listing of Jāderloon's® recommended annual preventive maintenance items.

Back to Resources

Tell Us About Your Project

Contact Us