Piedmont Specifications

Available Sizes:

  • Bay Widths – 30’, 32’, and 35’
  • Lengths – Any multiple of 12 ft.

Material Specifications:

  • Columns – 4”sq x 13ga tube (50,000 psi yield/55,000psi tensile)
  • Upper and lower truss members, roof purlins, and endwall verticals – 2”sq x 15ga tube (50,000psi yield/55,000psi tensile)
  • Endwall and sidewall horizontals and truss web members – 1½”sq x 16ga tube (45,000psi yield/48,000psi tensile)
  • Gutter – 10.4” wide x 1/8 thick aluminum  (35,000psi yield, 38,000psi tensile) Brace Cables – ¼” 7 x 19 galvanized steel

Design Criteria:

  • Column/truss spacing is 12’. All widths have five roof purlins.
  • Standard gutter heights are 8’ to 14’ in 2’ increments.
  • Lengths up to 48’ have one set of brace cables/column run, over 48’ two sets/column run.
  • Standard ratings are 30lb/sqft roof load and 90mph wind load.  Higher ratings are available with an increase in cost.

Cover Options and Sizes:

  • Roof – Polyethylene film (30’ wide/36’ poly, 32’ wide/36’ poly, 35’ wide/40’ poly)
  • Sidewalls and Endwalls – 8mm polycarbonate sheet, corrugated polycarbonate sheet, or polyethylene film

Request a Quote